toploader balances
Main Menu - home | productsservices | mass calibration | rentals | profile | links | sitemap | contact | search
Products - industrial scales | scanning | dimensioning | barcode systems | weigh labelers | in motion | weights | software | custom
 

GX Series

The GX Series features a revolutionary Super Hybrid Sensor (SHS) technology that improves response speed, accuracy and minimizes maintenance costs. SHS combines the best of magnetic force restoration and single point parallelogram load sensing technologies. Its unique design provides the fastest response speed in its class - just ONE second! And if the SHS ever needs to be repaired, intead of replacing the whole sensr, you just replace one of three parts. This means low maintenance costs. (An additional benefit of the new SHS is that the GX automatically performs self calibration using the internal mass when the balance detects ambient temperature changes.) For detailed specifications click here to download the brochure.

Lab Scales Ishida: AF | AJ | AnD: Orion | Newton | GX | GX-K | Everest | Gemini - Sartorius: Extend 0.0001 | 0.001 | 0.01

GX Series

toploader balances - GX Series

-

Notable Features

  • Capacity: 210 g to 8,100 g/Resolution: 0.001g to 0.1g
  • Fast, new Super Hybrid Sensor (SHS) gives you the ultimate in response speed--Just ONE Second!
  • Resolution Range among models: 1/60,000 to 1/600,000
  • Large, bright Vacuum Fluorescent Display - see the display even in the dark
  • Percentage, Counting Functions & Comparator functions
  • ACAI Counting Function for highly accurate counting
  • Bright, blue Vacuum Fluorescent Display
  • GLP/GMP/ISO Compliance
  • Options: Comparator Output (Dealer Installed Option) Analog Output (Dealer Installed Option) Glass Breeze Break Animal Weighing Pan Density Determination Kit for GX 200/400/600

Model

GX-200

GX-400

GX-600

GX-800

GX-1000

GX-2000

GX-4000

GX-6100

GX-6000

GX-8000

Weight Capacity

210g

410g

610g

810g

1010g

2100g

4100g

6100g

610g

8100g

Min Weighing Value

0.001g

0.001g

0.001g

0.001g

0.001g

0.01g

0.01g

0.1g

0.1g

0.1g

Repeatability (SD)

0.001g

0.001g

0.001g

0.001g

0.001g

0.01g

0.01g

0.01g

0.1g

0.1g

Linearity

±0.002g

±0.002g

±0.03g

610g

610g

±0.02g

±0.02g

±0.03g

±0.1g

±0.1g

Stabilzation Time

Approx. 1 second

Approx. 1.5 second

Sensitivity Drift

±2 ppm / °C (10°C-30°C / 50°F-86°F) Auto On

±5 ppm / °C (10°C-30°C / 50°F-86°F) Auto Off

Operating Temp

5°C to 40°C (41°F to 104°F), 85% RH or less (No condensation)

Sensing Method

Super Hybrid Sensor (SHS) *SHS: Patent Issued and pending

Display Type

Vacuum Fluorescent Display (VFD)

Display Fresh Rate

5 times/second or 10 times/ second

No. of Samples

10, 25, 50 or 100 pieces

Min. unit mass

0.001 g

0.01 g

Min. 100% Ref Mass

0.100g

1.00g

Min.100% weight

0.01%, 0.1%, 1% (Depends on reference mass stored)

Standard Serial I/F

RS-232C Interface with Windows Communication Tools (WinCT: included as CD-ROM)

Weighing pan

128 x 128mm (5.04 x 5.04 inch)

165 x 165mm (6.50 x 6.50 inch)

Calibration

Motor driven Internal Calibration

External Dimensions

210 W x 317 D x 86 H mm (8.27 x 12.48 x 3.39 inch)

AC Adapter

Confirm that the adapter type is correct for the local voltage and power receptacle

Power Consumption

Approx. 11VA (supplied by AC adapter)

Weight

Approx. 4.6kg

Approx. 5.1 kg

Internal Calibration
The GX internal calibration with an internal mass saves time and money. External calibration requires a great deal of skill, time and an expensive external mass. With our internal calibration with internal mass, there is no downtime while the technician calibrates the balance.

  • Automatic Self Calibration — Self-calibrates automatically when the balance detects ambient temperature changes.
  • One Touch Automatic Calibration — Lets you calibrate the balance on demand with just the push of one button.
  • Calibration is essential for accuracy in weighing. For example, in high resolution balances, changes in sensitivity drift can be caused by changes in the ambient temperature. Take the GX 600 for example, the weight might change by ±0.010g with a change of 10°C. (Sample’s weight: 500g)
  • The GX’s internal calibration mass is adjusted to an “OIML F1 class level.” by the standard balance calibrated with an “OIML E2 class level mass”. (The GX’s internal calibration mass is not “the standard mass for legal metrology” nor “OIML’s level of calibration mass.” Instead it is the mass for adjustment.)

Ultra Fast Response Speed - Just 1.5 Seconds!

  • Ultra Fast Response Speed–Just 1.5 Seconds.* Ideal for installation on filling machines.
  • Ultra High Performance with minimum maintenance costs.

Standard Windows Communication Tools Software
A free copy of WinCT-A&D’s powerful and flexible data collection software tool for virtually instant connection to a PC and a network of other devices.

Standard RS-232C
Incorporates bi-directional communication with a PC, printer or other peripheral device.

Contact us today: Toll Free: 1.800.268.3269 or by Email: inquiry@interweigh.ca

a
  home | productsservices | profile | links | sitemap
a
Copyright ® 2012 | Interweigh Systems Inc.| All Rights Reserved
Interweigh Systems Inc. 51 Bentley Street, Markham, Ontario, Canada, L3R 3L1
Phone: (416) 491-7001 ~ Toll Free: (800) 268-3269 ~ Fax: (905) 940-1711
Or contact us at one of our four locations: Markham, Mississauga, Woodstock and Montreal
company profile Search by Keyword products Contact Information Sitemap Links products Home Search by Products home